4.11 Viewing and Working with Graphic Test Results
To display graphic results of a timing record:
1. Retrieve the test record that you would like to view (See sections 4.2 and 4.3).
2. Click on the Graph/Results menu. The graphic results will be displayed as shown in
Figure 4. Click on the Graph/Results menu again to return to the tabulated test results
screen. Alternatively, you can press [CTRL]+[G] to toggle between the two views.
3. There are a total of 6 graphic results pages. Press the [Page Down] key to view the next
page. Press the [Page Up] key to view the previous page.
Figure 4 Graphic Test Results
NOTES
Contact channel ID’s are shown as C1, C2, and C3 on the left side of
the graph. Up to 12 contact channels can be displayed on one graphic
report page.
Voltage monitoring channel V1 is shown below contact channel C3.
Coil initiate current is shown as I1.
Contact Channel 1
(
C1
)
Contact Channel 2
(
C2
)
Contact Channel 3
(
C3
)
Volta
g
e Monitorin
g
Channel 1
(
V1
)
Coil Initiate Current
(
I1
)
Travel Curve
Vista de pagina 31